HomeEasy HE330v2

6 replies [Last post]
Pentala
Offline
Joined: 22 Oct 2011

Hello,

Has anyone tried the HE330v2 sockets? I've got a three pack of the sockets. All appear to work fine - but only on one code...i.e. I can program them all to one code but no more...i've tried changing the last hex digit as per other posts and the Wiki, however nothing other that '0' as the last digit will work...

 

[rf]
# v1. Up to 12 RF units may be defined.
# v2. Up to 96 RF units may be defined.
devices=4
rf1.off=01020320028A05DC028A05DC0514032004B00C029C4015CB1555555540 < -- Lidl socket from HAH shop - working OK
rf1.on=01020320028A05DC028A05DC0514032004B00C029C4015CB1555561600
rf2.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B0 < -- This code appears to work ok
rf2.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B0
rf3.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B2 < -- Will not work..
rf3.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B2
rf4.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B4 < -- Will not work..
rf4.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B4
rf1.label=RF 1
rf2.label=RF 2
rf3.label=RF 3
rf4.label=RF 4

 

Pentala
Offline
Joined: 22 Oct 2011
Ok - found the problem with

Ok - found the problem with the first post - i had transposed the on & off codes!

Only problem now is that all sockets appear to respond to all the codes despite the last hex digit being changed...? i.e the code for rf2 will control 2,3 & 4 - rf3 will control 2,3 & 4 etc - i've done the reset on the plugs as per the instructions (using Group 'Off')...

 

[rf]
# v1. Up to 12 RF units may be defined.
# v2. Up to 96 RF units may be defined.
devices=4
rf1.off=01020320028A05DC028A05DC0514032004B00C029C4015CB1555555540
rf1.on=01020320028A05DC028A05DC0514032004B00C029C4015CB1555561600
rf2.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B0
rf2.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B0
rf3.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B1
rf3.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B1
rf4.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B2
rf4.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B2

 

 

Pentala
Offline
Joined: 22 Oct 2011
RF - Help - HE330 / Nexa RF Units

Does anyone have any working codes for the HE330v2 units or possibly the Nexa units which appear to be identical to the new HE330 devices?

The HE330v2 does not have the learn button and automatically goes into learn mode for 10 seconds each time the power is disconnected and re-applied to the sockets.

Andy

brett
Offline
Providence, United States
Joined: 9 Jan 2010
care to comment

Derek can you comment to the support of the HE330v2 units on this thread?

aivo
Offline
Tallinn, Estonia
Joined: 2 Mar 2011
Working Nexa codes

Initially had same issue as Pentala.  Now have Nexa units working with codes below.
Most likely they are all "group codes" - for different groups then though.
Worked these out with a little trial/error and changing codes by 4 char segments.

Regards,
Aivo

[rf]
devices=5
rf1.label=Nexa 1
rf2.label=Nexa 2
rf3.label=Nexa 3
rf4.label=Nexa K6
rf5.label=Nexa K3
rf1.off=010201130A7301130113011304C9011300000C01271042199A59A59A6659A659A5A6665999A5A5B0
rf2.off=010201130A7301130113011304C9011300000C01271042199A59A599A65A6659A5A6665999A5A5B0
rf3.off=010201130A7301130113011304C9011300000C01271042199A59A659A59A6659A5A6665999A5A5B0
rf4.off=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A6665999A5A5B0
rf5.off=010201130A7301130113011304C9011300000C01271042199A59A59A6659A5A66659A65999A5A5B0
rf1.on=010201130A7301130113011304C9011300000C01271042199A59A59A6659A659A5A666599A65A5B0
rf2.on=010201130A7301130113011304C9011300000C01271042199A59A599A65A6659A5A666599A65A5B0
rf3.on=010201130A7301130113011304C9011300000C01271042199A59A659A59A6659A5A666599A65A5B0
rf4.on=010201130A7301130113011304C9011300000C0127104219A6599A59A59A6659A5A666599A65A5B0
rf5.on=010201130A7301130113011304C9011300000C01271042199A59A59A6659A5A66659A6599A65A5B0

Pentala
Offline
Joined: 22 Oct 2011
Working! - Thanks for the codes :-)

Aivo,

Thanks for the posting with the codes. Tried the first three and they work great!

I now have 4 RF plugs working, 1 x Lidl plug and 3 x HE plugs.

Would be good to find out what needs to be changed in the codes for different ID's for these plugs...

Thanks again,

Andy.

mark_baldwin
Offline
Blackburn, United Kingdom
Joined: 19 May 2012
I struggled for a while

I struggled for a while trying to discover new codes for these units but have now got an easy solution.

I erase all codes from the unit by pressing Group off during 'learn' then progam a remote key after cycling the power.

I then use the codes generated by the RF helper for bye bye standby units.

It seems these unit can accept either HE codes or BBSB codes.

I now have 16 units programmed :)

Hardware Info